ERPS settings are shown on Fig. 2.57; users should disable the DIP Switch Control first in
order to set up ERPS parameters.
Table 2.44
Choose whether to enable ERPS or not.
Choose whether to enable UERPS.
When UERPS is enabled, ring ports periodically
sent a “heartbeat” packet to peer ring ports in order
to determine whether the link path (etc. wireless
bridge) is failure or alive.
If peer ring port cannot receive “heartbeat”
packets over 3 packets, the ring port will enter
protection state.
Note: This function affect the recovery time to
more than 20 ms.
Set the Heartbeat Interval.
Range from 50 to 10000 milliseconds.
Create the ring by specifying the R-APS VLAN ID of
the ring.
VLAN ID ranges from 1 to 4094.
After enabling the ERPS and adding a RAPS VLAN, users can click on for
more details and configurations, which are shown on Fig. 2.58.
Fig. 2.58