Atop Industrial Serial Device Server
SE5408A/SE5416A Series
User Manual V 1.0
76
Figure 7.4
For setting as a TCP Client, please follow these steps.
Click on the COMX port under Serial on the left hand side.
Select TCP Client in the Link modes.
Only two communication modes are available here: RAW and Virtual COM which
definitions are the same as above in Mode.
Enter the preferred Destination IP and Port. This should match the IP settings of the
TCP Server program.
Enable and enter Destination IP 2 and Port 2 if necessary. Two different servers can be
set here (for redundancy), the second server has to be enabled by ticking the box.
Go to Response Behavior for more information on this setting. For serial settings, go to
Sec. 5.4.1. For Advanced settings, go to Sec. 5.4.2.
Scroll to the bottom and click on “Save Configuration” button to save the changes.